BYHPV - GORE-TEX JOINT SEALANT
- MSDS: BYHPV
- Manufacturer: W L GORE AND ASSOCIATES INC
- Product Name: GORE-TEX JOINT SEALANT
- National Stock Number: 8030-00F006180
Product Identification
Product ID:GORE-TEX JOINT SEALANT
MSDS Date:02/10/1993
FSC:8030
NIIN:00F006180
MSDS Number: BYHPV
Responsible Party
ELKTON, MD 21922-1010
US
Emergency Phone: 410-392-3200
Info Phone: 410-392-3200
Preparer: MATHEW ALICKNAVITCH
Cage: 0AMD8
Contractor
Telephone: 410-392-3200
Cage: 0AMD8
Ingredients
ETHYLENE, TETRAFLUORO- POLYMER (POLYTETRAFLUOROETHYLENE),
CAS: 116-14-3
RTECS: KX4025000
Fraction By Weight: 98-100%
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:OVERHEATING/BURNING RESULT IN
IRRITATION OF EYES, SKIN & RESPIRATORY TRACT/POLYMER FUME FEVER.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:POLYMER FUME FEVER-FLU-LIKE, FEVER, CHILLS,
SOMETIMES COUGH.
Medical Cond Aggravated by Exposure:PRE-EXISTING DISEASES OF LUNGS.
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR. GIVE CPR IF NEEDED. SKIN:
MELTED POLYMER, COOL RAPIDLY W/COLD WATER. DON'T ATTEMPT TO PEEL
POLYMER. INGESTION: DON'T INDUCE VOMITING. EYES: FLUSH W/PLENTY OF
WATER. OB TAIN MEDICAL ATTENTION IN ALL CASES.
Fire Fighting
Extinguishing Media:WATER, CO2, FOAM/DRY CHEMICAL. USE MEDIA
APPROPRIATTE FOR SURROUNDING AREAS.
Fire Fighting Procedures:DOESN'T BURN W/O EXTERNAL FLAME. WEAR POSITIVE
PRESSURE SCBA/CLOTHING TO PROTECT FROM HYDROGEN FLUORIDE GASES
WHICH REACT W/WATER TO FORM HYDROFLUORIC ACID.
Unusual Fire/Explosion Hazard:HAZARDOUS GASES/VAPORS PRODUCED IN FIRE
ARE HYDROGEN FLUORIDE, CARBONYL FLUORIDE, CO & LOW MOLECULAR WEIGHT
FLUOROCARBONS.
Accidental Release
Spill Release Procedures:COLLECT BY SWEEPING/VACUUM ANY LOOSE MATERIAL
TO PREVENT ACCUMULATION OF PRODUCT.
Handling
Handling and Storage Precautions:WEAR NEOPRENE GLOVES WHEN HANDLING
REFUSE FROM FIRE INVOLVING POLYTETRAFLUOROETHYLENE.
Other Precautions:SMOKING TOBACCO/CIGARETTES CONTAMINATED W/POLYMER
DUST, MAY CAUSE POLYMER FUME FEVER.
Exposure Controls
Respiratory Protection:NONE NORMALLY REQUIRED, BUT IF NECESSARY, USE
ONLY NIOSH APPROVED RESPIRATORS.
Ventilation:LOCAL EXHAUST VENTILATION WHEN HEATING/MELTING MATERIAL.
Eye Protection:SAFETY GLASSES
Other Protective Equipment:NONE
Supplemental Safety and Health
Chemical Properties
Spec Gravity:0.2-0.6
Solubility in Water:INSOLUBLE
Appearance and Odor:WHITE, MARSHMALLOWY CORD W/W/O ADHESIVE STRIP W/NO
ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:OVERHEATING, TEMP >600F-750F.
Hazardous Decomposition Products:THERMAL: PARTICULATE & GASEOUS
PRODUCTS, HYDROGEN FLUORIDE & CARBONYL FLUORIDE, CO, LOW MOLECULAR
WEIGHT FLUOROCARBONS.
Disposal
Waste Disposal Methods:DISPOSE OF IAW/FEDERAL, STATE & LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.